11 resultados para Respiratory System

em Deakin Research Online - Australia


Relevância:

100.00% 100.00%

Publicador:

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Asthma Pump Routine SFX is a sound effect of an asthma pump being checked and used.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Lung age, a simple concept for patients to grasp, is frequently used as an aid in smoking cessation programs. Lung age equations should be continuously updated and made relevant for target populations. We observed how new lung age equations developed for Australian populations performed when utilizing the Burden of Obstructive Lung Disease (BOLD)-Australia dataset compared to more commonly used equations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Better characterization of childhood wheeze phenotypes using newer statistical methods provides a basis for addressing the heterogeneity of childhood asthma. Outcomes of these phenotypes beyond childhood are unknown.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The role of nurses in cardiothoracic transplantation has evolved over the last 25 years. Transplant nurses work in a variety of roles in collaboration with multidisciplinary teams to manage complex pre- and post-transplantation issues. There is lack of clarity and consistency regarding required qualifications to practice transplant nursing, delineation of roles and adequate levels of staffing.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of our study was to establish whether rectal temperature recordings in humans could be replaced by a non-invasive skin temperature sensor combined with a heat flux sensor (Double Sensor) located at the forehead to monitor core body temperature changes due to circadian rhythms. Rectal and Double Sensor data were collected continuously for 24h in seven men undertaking strict head-down tilt bed-rest. Individual differences between the two techniques varied between -0.72 and +0.55 degrees C. Nonetheless, when temperature data were approximated by cosinor analysis in order to compare circadian rhythm profiles between methods, it was observed that there were no significant differences between mesor, amplitude, and acrophase (P>0.310). It was therefore concluded that the Double Sensor technology is presently not accurate enough for performing single individual core body temperature measurements under resting conditions at normal ambient room temperature. Yet, it seems to be a valid, non-invasive alternative for monitoring circadian rhythm profiles.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: We describe Pseudomonas aeruginosa acquisitions in children with cystic fibrosis (CF) aged ≤5-years, eradication treatment efficacy, and genotypic relationships between upper and lower airway isolates and strains from non-CF sources. METHODS: Of 168 CF children aged ≤5-years in a bronchoalveolar lavage (BAL)-directed therapy trial, 155 had detailed microbiological results. Overall, 201/271 (74%) P. aeruginosa isolates from BAL and oropharyngeal cultures were available for genotyping, including those collected before and after eradication therapy. RESULTS: Eighty-two (53%) subjects acquired P. aeruginosa, of which most were unique strains. Initial eradication success rate was 90%, but 36 (44%) reacquired P. aeruginosa, with genotypic substitutions more common in BAL (12/14) than oropharyngeal (3/11) cultures. Moreover, oropharyngeal cultures did not predict BAL genotypes reliably. CONCLUSIONS: CF children acquire environmental P. aeruginosa strains frequently. However, discordance between BAL and oropharyngeal strains raises questions over upper airway reservoirs and how to best determine eradication in non-expectorating children.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To use a population-level, public-hospital approach to compare the prevalence and cost of musculoskeletal diseases (MSD) with other clinical specialties.

Methods: A healthcare utilization survey of 4 million individual records over 4 years, from all major public hospitals in the state of Victoria (estimated population 4.8 million residents in 2000/01) from 1997/98 to 2000/01. Main outcome measures were inpatient episodes of care, bed-days, and outpatient clinic encounters. MSD was defined as the combination of orthopedics and rheumatology.

Results: After obstetrics, MSD was the most frequent outpatient service, with orthopedics accounting for 9.9% of all visits in 2000/01. The proportion of MSD outpatient encounters (on average 11.6% of the total) was constant over the study period. Among 26 medical specialties, MSD had the sixth highest number of inpatient episodes (6.2% in 2000/01), following renal dialysis (14.6%), general surgery (8.2%), obstetrics (7.6%), gastroenterology (7.1%), and general medicine (6.7%). MSD was the fifth highest consumer of bed-days, occupying on average 7.7% of all beds per annum in the period 1997/98 to 2000/01, behind psychiatry (10.1%), respiratory medicine (8.5%), rehabilitation (8.3%), and general medicine (7.8%). MSD was the third most-costly discipline in 2000/01, with total costs of over A dollars 169 million (9.7% of total inpatient costs that year), behind respiratory medicine (11.6%) and general surgery (11.5%).

Conclusion:
Compared to other diseases, MSD consumes a substantial proportion of healthcare resources in Victorian public hospitals. These data have important implications for allocation of healthcare resources, clinical care pathways, and prevention strategies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Respiratory events during sleep induce cortical arousals and manifest changes in autonomic markers in sleep disorder breathing (SDB). Finger photoplethysmography (PPG) has been shown to be a reliable method of determining sympathetic activation. We hypothesize that changes in PPG signals are sufficient to predict the occurrence of respiratory-event-related cortical arousal. In this study, we develop a respiratory arousal detection model in SDB subjects by using PPG features. PPG signals from 10 SDB subjects (9 male, 1 female) with age range 43-75 years were used in this study. Time domain features of PPG signals, such as 1) PWA--pulse wave amplitude, 2) PPI--peak-to-peak interval, and 3) Area--area under peak, were used to detect arousal events. In this study, PWA and Area have shown better performance (higher accuracy and lower false rate) compared to PPI features. After investigating possible groupings of these features, combination of PWA and Area (PWA + Area) was shown to provide better accuracy with a lower false detection rate in arousal detection. PPG-based arousal indexes agreed well across a wide range of decision thresholds, resulting in a receiver operating characteristic with an area under the curve of 0.91. For the decision threshold (PC(thresh) = 25%) chosen for the final analyses, a sensitivity of 68.1% and a specificity of 95.2% were obtained. The results showed an accuracy of 84.68%, 85.15%, 86.93%, and 50.79% with a false rate of 21.80%, 55.41%, 64.78%, and 50.79% at PC(thresh) = 25% or PPI, PWA, Area , and PWA + Area features, respectively. This indicates that combining PWA and Area features reduced the false positive rate without much affecting the sensitivity of the arousal detection system. In conclusion, the PPG-based respiratory arousal detection model is a simple and promising alternative to the conventional electroencephalogram (EEG)-based respiratory arousal detection system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Remote telemonitoring holds great potential to augment management of patients with coronary heart disease (CHD) and atrial fibrillation (AF) by enabling regular physiological monitoring during physical activity. Remote physiological monitoring may improve home and community exercise-based cardiac rehabilitation (exCR) programs and could improve assessment of the impact and management of pharmacological interventions for heart rate control in individuals with AF.

Objective: Our aim was to evaluate the measurement validity and data transmission reliability of a remote telemonitoring system comprising a wireless multi-parameter physiological sensor, custom mobile app, and middleware platform, among individuals in sinus rhythm and AF.

Methods: Participants in sinus rhythm and with AF undertook simulated daily activities, low, moderate, and/or high intensity exercise. Remote monitoring system heart rate and respiratory rate were compared to reference measures (12-lead ECG and indirect calorimeter). Wireless data transmission loss was calculated between the sensor, mobile app, and remote Internet server.

Results: Median heart rate (-0.30 to 1.10 b∙min-1) and respiratory rate (-1.25 to 0.39 br∙min-1) measurement biases were small, yet statistically significant (all P≤.003) due to the large number of observations. Measurement reliability was generally excellent (rho=.87-.97, all P<.001; intraclass correlation coefficient [ICC]=.94-.98, all P<.001; coefficient of variation [CV]=2.24-7.94%), although respiratory rate measurement reliability was poor among AF participants (rho=.43, P<.001; ICC=.55, P<.001; CV=16.61%). Data loss was minimal (<5%) when all system components were active; however, instability of the network hosting the remote data capture server resulted in data loss at the remote Internet server during some trials.

Conclusions: System validity was sufficient for remote monitoring of heart and respiratory rates across a range of exercise intensities. Remote exercise monitoring has potential to augment current exCR and heart rate control management approaches by enabling the provision of individually tailored care to individuals outside traditional clinical environments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Increased levels of particulate matter (PM) in the atmosphere have contributed to an increase in mortality and morbidity in communities and are the main contributing factor for respiratory health problems in the population. Currently, PM concentrations are sparsely monitored; for instance, a region of over 2200 square kilometers surrounding Melbourne in Victoria, Australia, is monitored using ten sensor stations. This paper proposes to improve the estimation of PM concentration by complementing the existing high-precision but expensive PM devices with low-cost lower precision PM sensor nodes. Our evaluation reveals that local PM estimation accuracies improve with higher densities of low-precision sensor nodes. Our analysis examines the impact of the precision of the lost-cost sensors on the overall estimation accuracy.